Midwest Guardrail System Placed Adjacent to 2:1 Fill Slope

Report Number(s): TRP-03-185-10

Description: Steel Post and W-Beam roadside barrier

Test Level: 3

Eligibility Letter: B211

MASH Test Number: 3-11

Proprietary/Non-proprietary: Non-proprietary

Pass/Fail: Pass

Evaluation: Testing + Engineering Analysis

Sponsor: Midwest States Regional Pooled Fund Program

Test Article Description

Height: 31"

Rail Type: W-Beam

Rail Thickness: 12-Gauge

Post Type: W6 x 9

Material: Steel

Post Total Length: 108"

Post Spacing: 6' 3"

Blockout Type: Wood

Blockout Depth: 14.25"

Aesthetic: No

Application: Slope

Special Configuration: Slope

Report(s):

MGS221-2 Report acrobat-icon

MGS221-2 FHWA Eligibility Letter B211 acrobat-icon