DESIGN OF CLOSED-SECTION POST FOR USE IN A NON-PROPRIETARY HIGHTENSION CABLE MEDIAN BARRIER

Report Number(s): TRP-03-380-19

Description: As part of research efforts to design a non-proprietary, high-tension, cable median barrier, closed-section posts were investigated through dynamic component testing. A closed-section post would mitigate the propensity for floor pan tearing and post penetration into the occupant compartment.

Test Level: 3

Barrier Type: High Tension

MASH Test Number: None

Proprietary/Non-proprietary: Non-proprietary

Pass/Fail: NA

Evaluation: Component Testing

Sponsor: Midwest Pooled Fund Program

Test Article Description

MASH Version: MASH16

Post Spacing: Yet to be updated

Post Material: Steel

Aesthetic: No

Report(s):

TRP-03-380-19